<LOGO>
FM Transmitter Measurement Report
Created: 2026-09-18 19-09-45
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 52 dBuV SANDELS
Pilot RDS Phase Difference
4.9 kHz 5.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 71 kHz 15885 27,0192
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,4 dBr 5,22 dBr 6,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7, 103.8 MHz -
FM Scope Max at: 71 kHz MIN: 10 kHz % above 76 kHz: 27,0192 Acquired: 2026.09.18 19.08.41 Total samples: 15885 Equivalent time: 0:13:14 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 6,5 dBr MIN: 2,4 dBr AVE: 5,22 dBr % above 12,2 dBr: 0,0 Last value: 5,4 dBr (2026.09.18 19.08.41) 18.54 18.56 18.58 19.00 19.02 19.04 19.06 19.08 0 2 4 6 Pm [dBr]